Dr. Pen M7S silver wireless microneedling pen hero product image

Dr. Pen M7S Silver | Pluma de Microneedling Inalámbrica

Solo pluma / CUALQUIERA
$79.80
Precio de oferta  $79.80 Precio habitual 
Ir directamente a la información del producto
Dr. Pen M7S silver wireless microneedling pen hero product image

Dr. Pen M7S Silver | Pluma de Microneedling Inalámbrica

$79.80
Precio de oferta  $79.80 Precio habitual 

Minorista autorizado

Garantía de un año

Envío gratuito en EE. UU.

Envío en 24 horas

Paquete
Tipo de consejos
$79.80
Precio de oferta  $79.80 Precio habitual 
Formas de pago
  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Descripción

Pluma de Microneedling Inalámbrica Profesional — Precisión sin Cable, Energía para Todo el Día

La Dr. Pen M7S Silver ofrece microneedling de nivel profesional donde sea que realices tu rutina. Impulsada por un motor sin escobillas silencioso, ofrece un rendimiento constante y de baja vibración en seis niveles de velocidad ajustables y un rango de profundidad de aguja de 0 a 2.5 mm. Completamente inalámbrica con carga rápida USB-C y hasta 4 horas de uso continuo por carga, la M7S Silver se adapta a cualquier entorno: hogar, estudio o en movimiento.

Características Clave

Inalámbrico y Recargable por USB-C
Batería incorporada con carga rápida USB-C — hasta 4 horas de uso continuo por carga
Control de Precisión de 6 Velocidades
Ajusta la velocidad del motor para adaptarla a tu intensidad preferida en cada paso de tu rutina
Profundidad Ajustable de 0-2.5 mm
El dial de profundidad de precisión te permite personalizar los ajustes para rostro, cuello, escote y cuerpo
Motor Sin Escobillas de Alto Rendimiento
Salida silenciosa y de baja vibración que se mantiene constante durante cientos de sesiones
Pantalla LED de Velocidad y Batería
Lectura en tiempo real — conoce siempre tu configuración de velocidad actual y la carga restante
Compatible con Cartuchos de la Serie M7/M8
Funciona con los 7 tipos de puntas: de 11 a 42 pines, Nano-R y Nano-S

Opciones de Paquete

Paquete Precio Lo que Obtienes
Solo Pluma $79.80 Dispositivo + cable USB-C + estuche de transporte
M7S + 10 Puntas $89.80 Dispositivo + 1 paquete (10 cartuchos) de tu tipo elegido
M7S + 20 Puntas $99.80 Dispositivo + 2 paquetes (20 cartuchos) — excelente valor para rutinas regulares
M7S + 30 Puntas ⭐ $110.80 Dispositivo + 3 paquetes (30 cartuchos) — Mejor Valor

Guía de Selección de Cartuchos
Cartucho Ideal Para
11-Pines Trabajo detallado y específico en áreas pequeñas
16-Pines Uso general en rostro y cuello — punto de partida recomendado para la mayoría de los usuarios
24-Pines Cobertura más amplia para sesiones faciales completas eficientes
36-Pines Cuerpo y cuero cabelludo — cobertura de área amplia en menos pasadas
42-Pines Máxima densidad de pines para las áreas de superficie más amplias
Nano-R (Redondo) Puntas nano ultrafinas para un cuidado suave a nivel superficial
Nano-S (Inclinado) Zonas contorneadas — puente de la nariz, área debajo de los ojos y línea de los labios

¿Nuevo en el microneedling? Comienza con 16-Pines para uso general, o Nano-R para las áreas más delicadas.

Modo de Uso
  1. Limpiar — Comienza con la piel limpia y seca. Retira todo el maquillaje e impurezas antes de iniciar tu sesión.
  2. Colocar un cartucho — Engancha un cartucho de un solo uso de forma segura en el cabezal del dispositivo antes de encenderlo.
  3. Ajustar profundidad y velocidad — Ajusta el dial de profundidad (0–2.5 mm) y selecciona un nivel de velocidad (1–6). Si eres principiante, comienza con los ajustes más bajos en ambos.
  4. Aplicar suero — Aplica una capa fina de tu suero preferido en el área. Esto reduce la fricción y favorece la absorción durante la sesión.
  5. Deslizar el dispositivo — Mueve el M7S Silver sobre tu piel en pasadas superpuestas horizontales, verticales y diagonales. Mantén el dispositivo perpendicular a la superficie en todo momento.
  6. Cuidado post-sesión — Aplica un suero calmante e hidratante o una mascarilla de tela. Evita ingredientes activos como retinoides y ácidos durante al menos 24 horas.
  7. Desechar y guardar — Retira y desecha el cartucho usado inmediatamente. Limpia el cabezal del dispositivo y guárdalo en el estuche de transporte.
Contenido de la Caja

Caja
Bandeja
Dr. Pen M7S
16 pines × 2 unidades
Manual del Producto
Adaptador
Cable


Para uso cosmético externo únicamente. No está destinado a diagnosticar, tratar, curar o prevenir ninguna enfermedad o condición. Consulta a un profesional de la piel con licencia antes de usarlo si tienes un problema cutáneo activo.

Gradient background transitioning from pink to yellow

Especificación

Nivel de velocidad:6 velocidades
Modelo de alimentación:Inalámbrico
Capacidad de la batería:380 mAh
Material del mango:Metal
Rango de ajuste de aguja:0-2.5 mm
Modo de carga:Interfaz USB tipo C
Cartuchos disponibles:11 / 16 / 24 / 36 / 42 / Nano-S / Nano-R

Dr. Pen M7S packing list showing microneedling pen, box, cartridges, charger, USB cable and user manual

Lista de empaque

Caja
Bandeja
Dr. Pen M7S
16 agujas × 2 uds.
Manual del producto
Adaptador
Cable

Dr. Pen M7S Silver | Pluma de Microneedling Inalámbrica - Feature Image 1
Dr. Pen M7S Silver | Pluma de Microneedling Inalámbrica - Feature Image 2

Preguntas frecuentes

What skin concerns can the Dr.Pen M7S help address?

The M7S is designed to help improve the appearance of uneven skin texture, enlarged pores, dullness, hyperpigmentation, and dark spots. It also significantly enhances the absorption of topical serums and skincare products, making your existing routine more effective. The adjustable needle depth (0–2.5mm) and 6 speed settings let you tailor each session to your face, neck, or scalp for a more even, refreshed-looking complexion.

How does the M7S compare to other Dr.Pen models like the M8S or A8S — and is it worth the upgrade?

The M7S is Dr.Pen's newest 2025 model, featuring a high-performance 16,000 RPM motor with ultra-quiet Advanced Oscillating Vertical Needling technology. Compared to the M8S, the M7S offers a more compact wireless form factor, a cleaner one-button LED interface, and a broader cartridge compatibility range. The A8S is better suited for users who prefer a slimmer pen-style grip and PMU-style precision. If you want a beginner-friendly yet professional-grade device with cordless convenience and versatile cartridge options, the M7S is an excellent choice.

What needle depth settings does the M7S offer, and how do I choose the right one?

The M7S allows you to adjust needle depth from 0 to 2.5mm in precise increments. For delicate areas like under the eyes, lips, and neck, start at 0.25–0.5mm on a low speed setting. General facial use works well between 0.5–1.5mm. Thicker skin areas such as the forehead, jawline, or scalp can benefit from 1.5–2.5mm. If you are new to microneedling, always begin at a shallower depth and gradually increase as your skin builds tolerance over multiple sessions.

Which cartridges are compatible with the Dr.Pen M7S?

The M7S is compatible with the full range of Dr.Pen M7S cartridges, including 9-Pin, 12-Pin, 16-Pin, 24-Pin, 36-Pin, 42-Pin, Nano-R, Nano-S, Nano-3D, and Nano-5D tips. Fine-gauge 11-pin and 16-pin cartridges (0.18mm needle diameter) deliver less discomfort and are ideal for sensitive skin areas. Nano cartridges work best for surface-level serum infusion without deep needling. Always use genuine Dr.Pen cartridges to ensure a secure fit, consistent needle depth, and safe results.

How often should I use the M7S, and how soon will I see results?

For standard microneedling sessions, we recommend spacing each session 4–6 weeks apart to give your skin adequate time to recover and renew. For nano-needling with Nano-R or Nano-S cartridges, sessions can be performed every 1–2 weeks and can even be scheduled between your regular microneedling sessions. Most users begin noticing visible improvements in skin texture and radiance after 2–3 sessions, with more significant results developing over continued use.

Is the M7S painful to use? Should I apply numbing cream beforehand?

Sensation levels vary based on needle depth, speed setting, and individual skin sensitivity. Most users find lower speed settings on delicate areas quite comfortable. For deeper depth settings or more sensitive skin types, applying a topical numbing cream (lidocaine-based) 20–30 minutes before your session can noticeably reduce any discomfort. Be sure to wipe off the numbing cream completely with a clean cloth before starting your session, and never use the device over irritated, broken, or inflamed skin.

What skincare ingredients should I use before and after a session?

Before your session, cleanse your skin thoroughly and apply a hydrating serum — hyaluronic acid is ideal — to reduce drag and support smooth glide. After your session, focus on calming and barrier-supporting ingredients: hyaluronic acid, peptides, and niacinamide are all well-tolerated on freshly needled skin. Avoid active ingredients including retinol, vitamin C (L-ascorbic acid), AHAs, BHAs, and benzoyl peroxide for at least 24–48 hours post-session, as the skin barrier is temporarily more permeable and sensitive.

Who should avoid using the M7S?

The M7S should not be used on active breakouts, open wounds, cold sores, or inflamed skin. Individuals with eczema, psoriasis, rosacea, or other active skin conditions should consult a dermatologist before use. Those who are pregnant, currently taking blood-thinning medications, or who have a known history of keloid formation should seek medical advice prior to use. If you have recently had laser resurfacing, chemical peels, or facial surgery, wait until your skin has fully healed before beginning microneedling.

Are the M7S cartridges reusable? How should I handle and store them?

Each cartridge is designed for single use only and must be properly disposed of after every session — even if you are the only user. Reusing cartridges introduces the risk of contamination, dull needles, and uneven penetration that can lead to skin irritation. After each session, remove the used cartridge, cap the pen tip, and wipe the exterior of the device with a clean, dry cloth. Store your M7S in its protective case in a cool, dry location away from direct sunlight and moisture.

What skin reactions should I expect after a session, and how long do they last?

Mild redness and a warm, flushed sensation immediately following your session are completely normal responses and typically resolve within 12–24 hours. Users with more sensitive skin may notice minor swelling or small pinpoint marks that fade within 24–48 hours. Avoid direct sun exposure for at least 48 hours after needling, and apply a broad-spectrum SPF 30+ sunscreen the following morning. Skip heavy makeup for the first 24 hours to allow your skin barrier to recover, and keep your post-session skincare routine simple and gentle.

También te puede gustar